TWIN-O-VAC MULTI-PURPOSE DEVICE

The Twin-O-Vac is a low cost versatile unit that is ideal when extra
or portable sources of oxygen or suction are required. Each
Twin-O-Vac uses one oxygen outlet (ie. An oxygen pipeline
wall point or cylinder regulator) to provide variable suction plus
two separate sources of oxygen. All three outlets can be used
simultaneously on up to three different patients if necessary.
The Twin-O-Vac can be connected or linked to an assortment of
equipment including resuscitators, flowmeters, infant warmers
and humidifiers.

SKU: N/A Category: Brand:

Description

Part No Gas Inlet Pressure Negative Pressure at Maximum Setting Free Air Displaced Gas Consumed Connections Inlet Connections Outlet
TM117G
Oxygen
400kPa
400mmHg
16 l/min
22 l/min
S.I.S Oxygen Handwheel
S.I.S Sleeve
518632
Oxygen
400kPa
150-200mmHg
16 l/min
22 l/min
S.I.S Oxygen Handwheel
S.I.S Sleeve
518633
Oxygen
50Psi
150-200mmHg
14 l/min
20 l/min
D.I.S.S Oxygen Handwheel
D.I.S.S
  • The light weight of the unit makes it easy to handle and lightens the load on pipeline outlets and regulators
  • Only three moving parts in the main control head
  • Reliable and durable
  • Standard millipore brand filter acts as a bacteria filter between the jar contents and room air
  • Adjustable suction control allows the suction level to be set and monitored
  • Easy to read dual scale (kPa and mmHg) vacuum gauge
  • Colour coded pressure gauges and identification labels for quick recognition of the gas used by the regulator
  • Gas specific inlet fittings and outlet fittings to prevent fitting to the wrong gas type
  • Suction outlet connection is a nominal 8mm I.D. tubing nipple
  • Twin-O-Vac (p/n TM117G) is 0 to -100 kPa
  • Twin-O-Vac (p/n 518632 & 518633) Gauge range is 0 to -25 kPa
  • Receiver Jar capacity of 400 ml
  • Weighs approximately 720 grams
  • ARTG ID: 159014

Applications:

The Twin-O-Vac is a low cost versatile unit that is ideal when extra or portable sources of oxygen or suction are required. Each Twin-O-Vac uses one oxygen outlet (ie. An oxygen pipeline wall point or cylinder regulator) to provide variable suction plus two separate sources of oxygen. All three outlets can be used simultaneously on up to three different patients if necessary. The Twin-O-Vac can be connected or linked to an assortment of equipment including resuscitators, flowmeters, infant warmers and humidifiers.

Common areas of use are general wards, transporting patients, emergency wards, ambulances, portable resuscitation kits, and paediatric wards.

Spare Parts Part Number
Spare Receiver Jar, 400ml
554024
Spare Bacteria Filter (pack of 100)
554050
Spare Bacteria Filter (pack of 25)
554051
Spare Vacuum Gauge, 0 to -100 kPa
552501

Additional information

Part No

TM117G